DCIM Data Center Power Distribution Monitoring Solution

Data Center

  • AC/DC
  • DI/DO
  • Multi channels
  • Modbus-RTU RS485

Feedback

What Do Our Customers Say?

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Highlight of Acrel DCIM Data Center Power Distribution Monitoring Solution?

Measure

  • Voltage, Current
  • Frequency
  • Active Power, Reactive Power
  • Power Factor
  • Harmonic

Circuits

  • 2 Channels of Incoming Line
  • AMC100 Series: 30/48 Channels of Outgoing Line
  • AMC16Z Series: 24/48 Channels of Outgoing Line

System

  • AC 220V
  • DC 48V, 240V, 336V

 Communication

  • AMC100-Z: 3 channels of RS485/Modbus-RTU
  • or 2 channels of RS485/Modbus-RTU + 1 Ethernet
  • AMZ16Z-Z: 1 channel of RS485/Modbus-RTU

Switchgear

What’s the Components of Acrel DCIM Data Center Power Distribution Switchgear?

On-site Photo

HUA DONG DATA CENTER

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

AMC100 Series

AMC100 DC & AC Networking

How does Acrel AMC100 Series DC & AC Multi Channels Electricity Meter work?

AMC100 Incoming Line Main Circuit Power Meter

AMC100-ZA

AMC100-ZD

AC

A+B independent 2-channel:
Full electrical parameter measurement, 63rd harmonic, Neutral current, neutral voltage
8DI4DO+1 temperature and humidity
Ethernet (optional)
3 channels RS485 (2 channels uplink touch screen and dynamic system, 1 channel downlink sub-module)
Comes with DC24V voltage output, power supply for 3 split modules + 1 touch screen

DC

A+B independent 2-channel:
Full electrical parameter measurement
8DI4DO+1 temperature and humidity
Ethernet (optional)
3 channels RS485 (2 channels uplink touch screen and dynamic system, 1 channel downlink sub-module)
Comes with DC24V voltage output, power supply for 3 split modules + 1 touch screen

AMC100 Outgoing Line Branch Circuit Power Meter

AMC100-FAK48
AMC100-FAK30

AMC100-FDK48
AMC100-FDK30

AMC100-FA48
AMC100-FA30

AMC100-FD48
AMC100-FD30

A+B independent 2-channel:
24 or 15 all-electric parameters on each side
48/30 active switch input
1 channel RS485 communication

A+B independent 2-channel:
24 or 15 all-electric parameters on each side
1 channel RS485 communication

AMC100 paired Current Sensor

AKH-0.66-W-9A
AKH-0.66-W-9B
AKH-0.66-W-15A
AKH-0.66-W-15B

AKH-0.66-EMS

AKH-0.66-W-9N-HB
AKH-0.66-W-12N-HB
AKH-0.66-W-20N-HB
AKH-0.66-W-30N-HB

AHKC-F

AHKC-BS-N

9A - 50A/50mA, φ9mm, 0.2 class, 10Ω
9B - 50A/50mA, φ9mm, 0.2 class, 10Ω
15A - 100A/50mA, φ15mm, 0.2 class, 10Ω
15B - 100A/50mA, φ15mm, 0.2 class, 10Ω

50A/10mA
50A/50mA
Din-rail

9N - 50A/50mA, φ9mm, 0.2 class, 10Ω
12N - 100A/50mA, φ12mm, 0.2 class, 10Ω
20N - 200A/50mA, φ20mm, 0.2 class, 10Ω
30N - 400A/50mA, 31*13mm, 0.2 class, 10Ω

Incoming Line
0-1000A/5V
43*13mm

Outgoing Line
100A/5V
20.5*10.5mm

AMC16Z Series

AMC16Z DC & AC Networking

How does Acrel AMC16Z Series DC & AC Multi Channels Electricity Meter work?

AMC16Z Incoming Line Main Circuit Power Meter

AMC16Z-ZA

AMC16Z-ZD

AC

A+B independent 2-channel:
Bus voltage, current, active power, reactive power, power factor,
active energy, reactive energy, 2-63rd harmonics of the three-phase main incoming line,
Neutral line current, neutral ground voltage,
6DI2DO, 2 leakage current, 1 temperature and humidity,
1 RS485 communication,
With DC24V voltage output, power supply for shunt module and touch screen

DC

A+B independent 2-channel:
Bus voltage, current, power, active energy of the main incoming line,
6DI2DO, 1 channel temperature and humidity,
1 channel RS485 communication,
Comes with DC24V voltage output to supply power to the shunt module and touch screen,
With 2 channels of ±12V voltage output, power supply for the main channel Hall sensor

AMC16Z Outgoing Line Branch Circuit Power Meter

AMC16Z-FAK24
AMC16Z-FAK48

AMC16Z-FDK24
AMC16Z-FDK48

AMC16Z-KA
(active)

AMC16Z-KD (passive)

A+B independent 2-channel:
Outgoing line voltage, 12/24 channels of current,
power and energy on each side,
24/48 active switch inputs,
1 channel RS485 communication

A+B independent 2-channel:
24-channel outgoing switch value collection on each side,
1 channel RS485 communication

AMC16Z-ZJY

AMC16Z-FJY

AMC16Z-D

AMC16Z-ZA-ZD

Monitor the busbar voltage, busbar-to-ground voltage, busbar insulation status, etc.
of the A+B dual DC incoming circuit.
One RS485 interface is used to connect to the touch screen or RS485 hub,
and it is also equipped with 6 RS485 interfaces for external digital intelligence.
Leakage current sensor, can measure up to 192 branches

It is selected when externally equipped with an analog leakage current sensor.
It is connected to the main module through the RS485 interface for monitoring the insulation state of the shunt.
It can be expanded to 8 sets at most.
It can be configured as the insulation state of 24 shunts of single-channel DC outlet,
and 1-channel RS485 communication.

Outgoing circuit built-in Current Sensor, din-rail installation
1-channel incoming line + 21-channel outgoing line full power + 21-channel active switch
4-channel passive DI+2DO
1 channel temperature + 1 channel zero sequence current + 1 channel leakage current
1-way zero-ground voltage detection

AC and DC integrated module
2 AC incoming lines + 1 DC incoming line
6 passive DI+2DO
1 channel temperature + 2 channel leakage current
Neutral ground voltage
With DC24V voltage output, power supply for shunt module and touch screen

AMC16Z paired Current Sensor

W-9N

W-12N

W-20

W-30

50a/50mA

100A/50mA

(5-200)A/20mA

(100-200)A/20mA
(200-400)A/50mA

W-9N

W-12N

AHKC-F

AHKC-BS

AHLC-LTA

50A/50mA

50A/25mA

Incoming Line
200-800A

Outgoing Line
50-500A

Outgoing Line
10mA / 5V

System

What’s the System of Acrel DCIM Data Center Power Distribution Monitoring?

Why choose us?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Lead Acid Battery Management System for IDC UPS

Standard:

ANSI/TIA-942

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Battery Temperature
  • Battery Voltage
  • Battery Internal Resistance
  • Charge and Discharge current
  • Ambient Temperature

Dual-circuit AC Power Meter for Data Center

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Measure Electricity
  •  Power Quality
  • Dual Incoming Circuits

63A Powertag Wireless Energy Sensor for Circuit Monitoring

Feature:
  • AC System
  • Single-phase
  • Three-phase
  • 10(63)A
  • 4G CE RS485
  • Real Time Monitoring
  • Alarm

Multi Channels Electricity Meter for Outlet Circuit in IDC

Certificate:

Feature:
  • Measure Electricity
  • Switch State
  • Modbus-RTU RS485
  • 24 or 48 channels
    Top