Protection & Control Motor Relay

ARD3M

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • Measure
  • Protect
  • Control
  • Communicate

Feedback

What Do Our Customers Say?

  • “ During the time I have worked with Acrel on this project, I have found Acrel and its team to be highly knowledgeable and results-driven. Based on preliminary pilot testing and a strong understanding of subsurface. ”

    Derek AuCoin

    Derek AuCoin 

    Defence Construction Canada

  • Acrel is one of the best supplier for me. They are so easy to communicate and very friendly. They even give an online tour of their factory. Looking forward for more business together in the future.

    Liezel 

    Philippines

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Acrel ARD3M Series Protection & Control Motor Relay?

Measure

  • U I P Q S PF F EP EQ
  • 2-63rd Harmonic
  • Leakage Current
  • Phase Unbalance

Protect

  • Fixed time overload
  • Inverse time overload
  • Starting timeout
  • Phase loss
  • Voltage unbalance
  • Current unbalance
  • Locked-rotor
  • under Load, Power, Voltage

Control

  • Protect type
  • Manual mode
  • Two-step model
  • Double speed mode
  • Star triangle three successive
  • Power Shake and start again

Communication

  • Standard Configuration:
  • 2 channels of Modbus-RTU
  • Optional:
  • Profibus DPV1
  • Profinet
  • Ethernet

ARD3M is suitable for low-voltage motor circuits with rated voltage up to 690V and rated current up to 800A.
Integrating protection, measurement, control, communication, operation and maintenance
Perfect protection function ensures the safe operation of the motor
Logic programmable function to meet a variety of control methods
Choose different communication modules to meet the needs of on-site communication
Split structure, composed of main body, display unit, transformer and communication module, suitable for installation in various cabinets

Specification

What’s the Specification of Acrel ARD3M Series Protection & Control Motor Relay?

The  standard  switch  quantity  of ARD3M  is  10DI  and  6DO, and  the  switch  quantity  type  is shown  in  Table  1:

Main switch classification

 

Code

 

DI is the dry contact and the external power supply

of DO is AC220V

K1
DI is the wet contact, the input is DC110V, and the

the external power supply of DO is AC220V

K2
DI is the wet contact, the input is DC220V, and the

the external power supply of DO is AC220V

K3
DI is the wet contact, AC220V input, and DO

the external power supply is AC220V

K4

 

The corresponding to  relation  between  ARD3M  current  specification  and  the  rated  current  and power  of  the  applicable  motor  is  shown  in  Table  2:

Protector

current

specification (A)

Ratio

setting

Primary side coil number of

transformer

Applicable scope of motor (kW) Suitable for motor

Rated current

range(A)

1 Support 5 0.12-999 0.1-5000
5 Support 1 0.12-999 0.5-5000
25 Not Support 1 3-11 6.3-25
100 Not Support 1 15-45 25-100
250 Not Support 1 55-132 63-250
800 Not Support 1 160-250 250-800

 

Additional  features  of  ARD3M  are  shown  in  Table  3:

Additional function Code Additional function Code
2-63 harmonic voltages and currents H Waveform recording WR
Additional Communication Module (optional) 1channel PROFIBUS

DPV1communication

CP Anti-electric shock function SU
2 channel PROFIBUS

DPV1 communication

2CP Insulation monitoring Ri
Ethernet communication

(MODBUS TCP  protocol)

MCE Electric leakage protection L
1channel Profinet

communication

PNET Fault record SR
1 channel 4-20mA output M1 2 channel 4-20mA output M2
Wireless capability (can be optional when Color dot matrix LCD is selected) WIFI

 

See Table 4 for the ARD3M Display Module:

Display module Code
Black and white dot matrix LCD, module size 98×60, opening  92×55(unit  mm) 60L1
Color dot matrix LCD, module size 98×60,cut-out 92×55(Unit    mm) 60L2

Parameter

What’s the Parameter of Acrel ARD3M Series Protection & Control Motor Relay?

Technical parameters Technical indicators
Protector auxiliary power supply Support two power modules, AC 220V power module (AC85-265V/DC100-300V) default, AC 380V power module (AC/DC100-415V) optional
Rated working voltage of the motor AC220V / 380V / 660V,50Hz / 60Hz
Rated operating current of the motor 1 (0.1A-5000A) External current transformer
5 (0.1A-5000A)
25(6.3A-25A)
100(25A-100A)
250(63A-250A)
800(250A-800A)
Relay output contact capacity Impedance load AC250V、10A
Switching input 10 channels of passive dry contact (active DC110V, DC220V, AC220V input can be optional)
Communication Standard supplied 2channel MODBUS RTU communication
Optional(only one can be selected) 1-2 channel PROFIBUS DPV1communication、1channel PROFINET communication、Ethernet communication(MODBUS TCP protocol)
Environment Working temperature -10ºC~55ºC
Storage temperature -25ºC~70ºC
Relative humidity ≤95﹪No condensation, no corrosive gas
Altitude ≤2000m
Pollution levels Class 3
Protection grade Main body IP20, split display module IP54 (installed on the cabinet panel)
Installation category Level III

Typical Topology

How does Acrel ARD3M Series Protection & Control Motor Relay work?

Installation

How to Install the Acrel ARD3M Series Protection & Control Motor Relay?

Leakage Current Protection

Onsite-Photo

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Why choose us?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Acrel ARD3M ИНТЕЛЛЕКТУАЛЬНОЕ УСТРОЙСТВО ЗАЩИТЫ ДВИГАТЕЛЯ

Standard:

IEC 60947-4-1:2018

IEC 60947-5-1:2016

Certificate:

Feature:
  • 690V Low Voltage Motor
  • Measure, Protect, Control
  • 10DI/6DO, 2AI DC4-20mA
  • Modbus-RTU, Profibus, Profinet, Ethernet

Acrel ARD3M Intelligent Motor Protection Device

Standard:

IEC 60947-4-1:2018

IEC 60947-5-1:2016

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 690V Low Voltage Motor
  • Measure, Protect, Control
  • 10DI/6DO, 2AI DC4-20mA
  • Modbus-RTU, Profibus, Profinet, Ethernet

Smart Motor Protector

Standard:

IEC 60947-4-1:2018

IEC 60947-5-1:2016

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 660V Low Voltage Motor
  • Measure, Protect, Control
  • 9DI/5DO, 2AI DC4-20mA
  • Modbus-RTU, Profibus-DP
    Top