63A Remote Control IoT-based Miniature Circuit Breaker

ASCB1

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • 6~63A
  • C & D Curve
  • Protection
  • WIFI 4G Ethernet RS485

Feedback

What Do Our Customers Say?

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

Application

  • Cell Tower
  • EV Charger Station
  • Smart Building
  • Smart Street Lighting
  • Smart Factory
  • Smart Apartment

Inspection lock design

  • Line maintenance
  • Equipment replacement
  • Temporary power failure
  • press and hold the control button to make the circuit breaker enter the lock-off state

Protection

  • Short Circuit
  • Over / Low Current/ Voltage/ Power
  • Over Temperature
  • Leakage Current

 Measure

  • Voltage, Current
  • Active Power, Reactive Power
  • Power Factor
  • Frequency
  • Active Energy, Reactive Energy

ASCB1 series intelligent miniature circuit breaker is a new intelligent power consumption product launched by Acrel Electric Co., Ltd.
The product consists of two parts: intelligent miniature circuit breaker and intelligent gateway.
It can be used for real-time monitoring of key electrical factors of power lines, such as voltage, current, power, temperature, leakage, energy consumption, etc.
It has the functions of remote control, early warning protection, short circuit protection, electric energy metering statistics, fault location, etc.
It is applied to low-voltage terminal power distribution network in the fields of industrial, commercial, civil buildings and infrastructure in indoor buildings and similar places.

Network

How does Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

Telecom Tower
Smart Building
Smart Factory
Apartment
Street Lighting
EV Charger

Installation

How to Install Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

Step1: Connect the RS485 port on the gateway to the BUS port of the circuit breaker by using the communication cable provided by the gateway

Step2: Insert the barbed side of the connecting wire of the circuit breaker into the external terminal of the previous circuit breaker toward the outside of the terminal, and the colors need to be matched one by one.

On-Site Photo

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Function

What’s the Function of Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

ASCB1 Series Intelligent MCB Function
 
 
ASCB1-63
· Can monitor voltage, current, power, power and temperature in real time
· with overpressure, underpressure, overload, short circuit, overcurrent, and overtemperature and other protection functions
· With local manual lever, local electric control, local lock, remote control, timing control and other control function
· Guide rail type installation, optional pole number 1P / 2P / 3P / 4P
· Standard RS-485 (MODBUS) communication; optional buckle curve type C / D
 
 
ASCB1LE-63
· Real-time monitoring of voltage, current, power, electric energy, temperature and leakage and other parameters
· With overvoltage, undervoltage, overload, short circuit, overcurrent, ultra-moderate leakage and other protection functions
· With local manual lever, local electric control, local lock, remote control, timing control and other control functions
·Guide rail type installation, optional pole number 2P / 4P; standard RS-485 (MODBUS) communication; optional buckle curve type C /D type.

What’s the Function of Acrel ASCB1 Series Gateway?

ASCB1 Smart Gateway Function
 
 
 
ASCB1-M-CE
· Can connect to up to 16 intelligent micro circuit breakers
· See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
· You can view the fault, alarm and separation status of each intelligent micro circuit breaker
· It can set and control the parameters for each intelligent micro circuit breaker
· Din rail type installation, LCD LCD display
· Support event logging; support RS485 communication
· Support for Ethernet communication.
 
 
 
ASCB1-M-4G
· It can connect to up to 16 smart micro circuit breakers
· Can see the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
· Can view the fault, alarm and separation status of each intelligent micro circuit breaker
· It can set and control the parameters for each intelligent micro circuit breaker
· Din rail type installation; LCD LCD display
· Support event logging; support RS485 communication
· Support for 4G network communication

Parameter

What’s the Parameter of Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

Model
ASCB1-63
ASCB1LE-63
Pole
1P/2P/3P/4P
2P/4P
Grade of Shell
63A
Rated Voltage
230V(1P/2P)、400V(3P/4P)
Rated Current
6A,10A,16A,20A,25A,32A,40A,50A,63A
Instantaneous Unbuckle Type
C/D
Rated Short-circuit Breaking Capacity
6000A
 
 
 
 
 
 
 
 
Protect
Over-current Protection
Default 100% rated current alert,
110% Rated current trip with adjustable threshold
Short-circuit Protection
5-10 Rated current for 0.04 seconds for circuit break protection
Overload Protection
Default 100% rated power alert,110% Rated power trip with adjustable threshold
Over-voltage Protection
Default 110% rated voltage alert,120% rated voltage trip with adjustable threshold
Under-voltage Protection
Default 90% rated voltage alert,80% rated voltage trip with adjustable threshold
Over-temperature Protection
Default 80℃ alert,100℃ trip, the threshold is adjustable
Leakage Protection
No
Default 20mA alert, 30mA trip, the threshold is adjustable
Leakage self-Inspection
No
Manual button self-inspection
Mechanical Life
20000 times
Electrical Life
6000 times
Levels of Protection
IP20
Connection Capacity
1-35mm²
Elevation Requirements
2000m
Ambient Temperature
-10℃~55℃,the average temperature at 24h was no higher than 40℃
Environmental Requirements
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative Humidity
At + 40℃, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature
-20℃-70℃
Class of Pollution
Installation Type
Way to Installation
Standard 35mm guide rail installation

What’s the Parameter of Acrel ASCB1 Series Gateway?

Product Model
ASCB1-M-4G
ASCB1-M-CE
Power Supply
AC 220V
Consumption
≤30W
Communication
4G
Ethernet
Display
LCD dot-matrix
Incident Record
Up to 20 alarm, fault and action records each
Protocol
Modbus、MQTT and so on
Elevation Requirements
2000m
Ambient Temperature
-10℃-55℃,24h the average temperature is not higher than 40℃
Environmental Requirements
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative Humidity
At + 40℃, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature
-20℃-70℃
Levels of Protection
IP20
Way to Installation
 Standard 35mm guide rail installation

Specification

What’s the Specification of Acrel ASCB1 Series 63A Remote Control IoT-based Miniature Circuit Breaker?

ASCB1-63-C16-1PLengthWidthHeightPolePhaseWires
Parameter(mm)1093675.51single1
ASCB1-63-C32-2PLengthWidthHeightPolePhaseWires
Parameter(mm)1095475.52single2
ASCB1-63-C63-3PLengthWidthHeightPolePhaseWires
Parameter(mm)1097275.53three3
ASCB1-63-C63-4PLengthWidthHeightPolePhaseWires
Parameter(mm)1099075.54three4
ASCB1LE-63-C63LengthWidthHeightPolePhaseWires
Parameter(mm)1099075.54three4
ASCB1-MLengthWidthHeight
Parameter(mm)1093675.5

FAQ

Got a Question? Get your Answer

Can the circuit breaker data be collected through RS485 communication?

The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

How many circuit breakers can a gateway carry?

16 PCS

How Gateways and Circuit Breakers are Networked?

The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway

Does the circuit breaker need to be equipped with additional accessories?

1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable

Why choose us?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

AC 1 Three-phase or 3 Single-phase Energy Meter for Cell Phone Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

Two Channels DC Energy Meter

Standard:

2014/30/EU

2014/35/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Dual DC Circuits
  • Secondary RS485
  • DC1000V
  • 5s Accuracy

DC12V Auxi. Power RS485 Modbus-RTU AC Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • DC12V /DC24V Power Supply
  • 4 Tariffs
  • Temperature
  • Leakage Current

Lead Acid Battery Management System for IDC UPS

Standard:

ANSI/TIA-942

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Battery Temperature
  • Battery Voltage
  • Battery Internal Resistance
  • Charge and Discharge current
  • Ambient Temperature

AC 6 Three-phase or 18 Single-phase Multi Circuit Panle Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Monitor: Grid, Generator, Air Conditioner, Lighting, etc
  • Active 2DI + Passive 4DI + 2DO
  • Up to 4 channels of Three-phase
  • or 12 channels of Single-phase
  • 2 NTC Temperature

AC Three-phase Panel Meter for Telecommunications Tower

Standard:

EN 62368-1:2014+A11:2017

EN 61000-3-12:2011

EN 61000-3-3:2013

EN 61000-6-1:2007

EN 61000-6-3:2007/A1:2011/AC:2012

IEC 62052-11:2003
IEC 62053-22: 2003

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Monitor Grid and Generator
  • AC/DC 85-265 Power Supply
  • Rated 660V, 5A
  • 4DI/2DO
  • RS485

DC 3 Channels Energy Meter for Mobile Phone Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

Split Type Hall Current Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

DC24V Auxi. Power RS485 Modbus-RTU AC Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless
  • 4 Tariffs
  • Temperature
  • Leakage Current

AC DC Energy Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

    Top