AC Three-phase Panel Meter for Telecommunications Tower

AMC96L-E4

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • Grid
  • Generator
  • 4DI/2DO
  • RS485

Feedback

What Do Our Customers Say?

  • “ During the time I have worked with Acrel on this project, I have found Acrel and its team to be highly knowledgeable and results-driven. Based on preliminary pilot testing and a strong understanding of subsurface. ”

    Derek AuCoin

    Derek AuCoin 

    Defence Construction Canada

  • Acrel is one of the best supplier for me. They are so easy to communicate and very friendly. They even give an online tour of their factory. Looking forward for more business together in the future.

    Liezel 

    Philippines

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Highlight of Acrel AMC Series AMC96L-E4 AC Three-phase Panel Meter for Telecommunications Tower?

Function

  • Monitor Grid and Generator
  • Digital: 4DI / 2DO

Rated

  • Voltage: 660V
  • Current: 5A

Power Supply

  • AC 85-265V
  • DC 85-265V

 Communication

  • Protocol: Modbus-RTU
  • Interface: RS485

Parameter

What’s the Parameter of Acrel AMC Series AMC96L-E4 AC Three-phase Panel Meter for Telecommunications Tower?

Technical Parameters Value
Input Connection Single phase-2 wire,3 phase-3 wire,3 phase 4-wire
Frequency 45-65Hz
Voltage Rating:

Single-phase:AC 100V、400V

Three-phase:AC 3×57.7V/100V(100V)、3x220V/380V(400V)

3x380V/660V(660V)(96 size only)

Note:72 profile not suitable for high voltage application

 

Overload:1.2 fold rating(continuous):2 fold rating for 1 second
Power consumption:<0.5VA
Current Rating:AC 1A、5A
Overload:1.2 fold rating(continuous):10 fold rating for 1 second
Power consumption:<0.5VA
Output Electric energy Output mode:open-collector photo-coupler pulse
Pulse constant:10000imp/kWh(settable),see wiring diagram for details
Communication RS485 port,Modbus-RTU protocol,DLT645 protocol(versions 09 and 97),baud rate 1200-38400
Function Switching input Dry contact input,built-in power supply
Switching output Output mode:Relay normally open contact output
Contact capacity:AC 250V/3A、DC 30V/3A
Analog output 1-5V,4-20mA
Accuracy Class Frequency:0.05Hz,Current、Voltage;0.2 class,Reactive

Power:1.0 class,Reactice Electric energy:1.0 class active

Power:0.5 class,active electric energy:0.5 class,2-31th harmonic

measurement:±1%

Power Supply AC/DC 85-265V     Power consumption≤10VA
Security Power frequency

withstand voltage

Between Power supply//Switching Output//Current input//voltage input and

Transmitting//Communication//Pulse Output//switching input AC 2kV 1min;

Between Power supply、switching output、Current input、voltage input AC 2kV 1min;

Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min;

Insulation resistance Input、Output end to machine enclosure>100MΩ
Environment Temperature work:-25℃~+65℃ storage:-40℃~+80℃
Humidity ≤93%RH Non-condensing
Altitude ≤2500m

Dimension

What is the Dimension of Acrel AMC Series AMC96L-E4 AC Three-phase Panel Meter for Telecommunications Towerk?

Network

How does the Acrel AMC Series AMC96L-E4 AC Three-phase Panel Meter for Telecommunications Tower work?

Wiring

How to Wire the Acrel AMC Series AMC96L-E4 AC Three-phase Panel Meter for Telecommunications Tower?

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

DC24V Auxi. Power RS485 Modbus-RTU AC Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless
  • 4 Tariffs
  • Temperature
  • Leakage Current

Multi Channels Dual Source Power Meter for Cell Phone Tower

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase or 12 Channels of Single-phase
  • Communication RS485 Modbus-RTU
  • Identify Generator or Utility Power

Power Meter and Battery Monitoring Solution for Telecom Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC&DC System
  • 12 DC channels Max.
  • 8 Three-phase Max.
  • 24 Single-phase Max.
  • Dual Source
  • DI/DO
  • Temp.&Humidity

PowerTag for Circuit Monitoring

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC System
  • Single-phase
  • Three-phase
  • 10(63)A
  • 4G CE RS485
  • Real Time Monitoring
  • Alarm

DC48V Auxi. Power DC Meter with 6 Citcuits

Standard:

EN 61326-1-2013

EN IEC 61000-3-2:2019+A1:2021

EN 61000-3-3:2013+A2:2021

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Rated -48V DC
  • 6 DC channels
  • Utility Monitor
  • Power for Hall Sensor

Rectangular Split Hall Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

AC 1 Three-phase or 3 Single-phase Energy Meter for Cell Phone Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

Two Channels DC Energy Meter

Standard:

2014/30/EU

2014/35/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Dual DC Circuits
  • Secondary RS485
  • DC1000V
  • 5s Accuracy

AC DC Energy Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

Multi Channels Meter with -48VDC for Cell Tower

Standard:

2014/30/EU

EN 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • -DC48V Auxi. Power
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase or 12 Channels of Single-phase
  • Communication RS485 Modbus-RTU
  • Identify Generator or Utility Power
    Top