DC12V Auxi. Power RS485 Modbus-RTU AC Energy Meter

ADW300-DC12V

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • DC12V
  • DC24V
  • 1 Channel of Residual Current
  • RS485 MODBUS-RTU

Feedback

What Do Our Customers Say?

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Acrel ADW300 Series DC12V RS485 Modbus-RTU Meter for Cell Tower?

Monitor

  • Electrical Parameters
  • U I P Q S PF, 2-31st Harmonic, Max Demand, etc

Optional Function

  • 4DI/2DO, 4 NTC Temperature, 2 Residual Current, 2 RS485, Power Outage Alarm

  Communication

  • WiFi 4G MQTT
  • Lora Lorawan
  • RS485 Modbus-RTU

Power Supply

  • DC12V
  • DC24V
  • AC85-265V
  • AC380V
  • AC690V

Specification

What’s the Specification of Acrel ADW300 Series DC12V RS485 Modbus-RTU Meter for Cell Tower?

Multiple Communication Methods

● 4G LTE

● NB-IoT

● WiFi (2.4GHz&5GHz)

● LoRa

● RS485 (MODBUS-RTU)

● Paired with IoT Energy Monitoring System

 Power Quality Analysis

● Total Harmonic

● 2nd~31st Harmonic

● Voltage Unbalance

● Current Unbalance

 Expanded Function

● 2-channel DO (Digital Ouput)

● 4-channel DI (Digital Input)

● 4-channel Cable Temperature Monitoring

● 1-channel Residual Current Measurement

 Alarm Function

● Over/Under Current

● Over/Under Voltage

● Over/Under Power

● Phase Loss

Parameter

What’s the Parameter of the Acrel ADW300 Series DC12V RS485 Modbus-RTU Meter for Cell Tower?

Parameter Description & Value
Voltage

Input

Rated Voltage 3×380~456Vac L-L or 3×660~792Vac L-L (via direct connection)

3×100~120Vac L-L (via PTs)

Reference Frequency 45~65Hz
Power Consumption <0.5VA (each Phase)
Current

Input

Rated Current 3×1(6)A AC (via CTs)
Starting Current 1% Ib (Class 0.5); 4% Ib(Class 1)
Power Consumption <1VA (each Phase)
Phase

Wiring

3P4W 3-phase 4-wire
3P3W 3-phase 3-wire
Auxiliary

Power

Supply

Voltage Range 85~265Vac
Power Consumption <2W
Measurement

Performance

Standard IEC 62053-22:2003;  IEC 62053-21:2003
kWh Accuracy Class 0.5S
Pulse Width of Pulse 80±20ms
Pulse Constant 6400imp/kWh; 400imp/kWh

Installation

How to Install the Acrel ADW300 Series DC12V RS485 Modbus-RTU Meter for Cell Tower?

3-phase 4-wire CT operated 3-phase 3-wire CT operated

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Two Channels DC Energy Meter

Standard:

2014/30/EU

2014/35/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Dual DC Circuits
  • Secondary RS485
  • DC1000V
  • 5s Accuracy

AC DC Energy Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

DC24V Auxi. Power RS485 Modbus-RTU AC Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless
  • 4 Tariffs
  • Temperature
  • Leakage Current

Rectangular Split Hall Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

Lead Acid Battery Management System for IDC UPS

Standard:

ANSI/TIA-942

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Battery Temperature
  • Battery Voltage
  • Battery Internal Resistance
  • Charge and Discharge current
  • Ambient Temperature

AC Three-phase Panel Meter for Telecommunications Tower

Standard:

EN 62368-1:2014+A11:2017

EN 61000-3-12:2011

EN 61000-3-3:2013

EN 61000-6-1:2007

EN 61000-6-3:2007/A1:2011/AC:2012

IEC 62052-11:2003
IEC 62053-22: 2003

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Monitor Grid and Generator
  • AC/DC 85-265 Power Supply
  • Rated 660V, 5A
  • 4DI/2DO
  • RS485

Split Type Hall Current Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

AC 6 Three-phase or 18 Single-phase Multi Circuit Panle Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Monitor: Grid, Generator, Air Conditioner, Lighting, etc
  • Active 2DI + Passive 4DI + 2DO
  • Up to 4 channels of Three-phase
  • or 12 channels of Single-phase
  • 2 NTC Temperature

AMC16-DETT -48V DC Energy Meter for American Tower

Standard:

EN 61326-1-2013

EN IEC 61000-3-2:2019+A1:2021

EN 61000-3-3:2013+A2:2021

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Rated -48V DC
  • 6 DC channels
  • Utility Monitor
  • Power for Hall Sensor

63A Remote Control IoT-based Miniature Circuit Breaker

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Protection
  • WIFI 4G Ethernet RS485
  • C Curve

  • Real Time Measurement
    Top