AMC16-DETT -48V DC Energy Meter for American Tower

AMC16-DETT

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • Rated -48V DC
  • 6 channels DC
  • Utility Monitor
  • Power for Hall

Feedback

What Do Our Customers Say?

  • “ During the time I have worked with Acrel on this project, I have found Acrel and its team to be highly knowledgeable and results-driven. Based on preliminary pilot testing and a strong understanding of subsurface. ”

    Derek AuCoin

    Derek AuCoin 

    Defence Construction Canada

  • Acrel is one of the best supplier for me. They are so easy to communicate and very friendly. They even give an online tour of their factory. Looking forward for more business together in the future.

    Liezel 

    Philippines

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

NERHighlight

What’s the Highlight of AMC16-DETT -48V DC Energy Meter for American Tower?

Function

  • Monitor device of Multipile Communication Operators

Circuit

  • Up to 6 channels of DC Current
  • Connect Hall Sensor 0-5V

Power Supply

  • DC -48V
  • ±12V Power Supply for Hall Sensor

 Communication

  • Protocol: Modbus-RTU
  • Interface: RS485

Parameter

What’s the Parameter of AMC16-DETT -48V DC Energy Meter for American Tower?

Technical parameter Index
input DC rated voltage 1 channel: -48VDC
DC current 6  channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V.
Commercial power monitoring 1 channel: 0-5VDC
Overload capacity Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors) 1%In≤I≤10%In    error±2.5%; I>10%In error±2%
Measurement resolution Voltage output accuracy 0.01V;    current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh
functions Basic function Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication
Metering function Start current: under rated voltage, when the load current value of the meter doesn’t exceed  1%  of the max.  current, the meter starts.
Shunt running  current: when there is no current  in  the  current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator  hall not have more than one digital change
Alarm function DC  voltage  output  low  alarm, DC  voltage  output  high  alarm, one power down alarm, module voltage loss alarm, metering branch error  alarm,  internal  program  error  alarm,  clock  error  alarm, memory failure alarm, AC input power failure alarm
Timing function support broadcast timing, could remote timing to the meter through RS485 communication.
Communication Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.Communication protocol: standard or custmized
Hall sensor power
supply
Power supply output:+12V/100Ma, -12V/50mA
Clock accuracy ≤0.5S/d(23℃),  ≤1S/d(-20℃-60℃),
Auxiliary power supply Voltage range -40V~-60VDC
Power consumption Whole device≤2W( no hall power supply output)
Storage It has the storage function of historical power data and historical
alarm information and the memory is 2MB
Insulation resistance ≥40MΩ
environment Temperature Working: -20℃~+60℃; storage:-40℃~+70℃
Humidity ≤98% no condensation, no corrosive gas place
Altitude ≤4000m
Protection level IP20
Material flame retardent Terminal glow wire temperature 960℃±10℃, shell glow wire temperature 6500℃±15℃
installation Standard 35mm din rail
Lightning protection Voltage input
(deferential mode)
Peak value 5kA
Auxiliary power supply
(deferential mode)
Peak value 5kA

Network

How does the AMC16-DETT -48V DC Energy Meter for American Tower?

Installation

How to Install the AMC16-DETT -48V DC Energy Meter for American Tower?

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Multi Channels Dual Source Power Meter for Cell Phone Tower

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase or 12 Channels of Single-phase
  • Communication RS485 Modbus-RTU
  • Identify Generator or Utility Power

Two Channels DC Energy Meter

Standard:

2014/30/EU

2014/35/EU

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Dual DC Circuits
  • Secondary RS485
  • DC1000V
  • 5s Accuracy

Power Meter and Battery Monitoring Solution for Telecom Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC&DC System
  • 12 DC channels Max.
  • 8 Three-phase Max.
  • 24 Single-phase Max.
  • Dual Source
  • DI/DO
  • Temp.&Humidity

DC12V Auxi. Power RS485 Modbus-RTU AC Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • DC12V /DC24V Power Supply
  • 4 Tariffs
  • Temperature
  • Leakage Current

Rectangular Split Hall Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

Split Type Hall Current Sensor for Cell Tower DC Energy Meter

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

AC 6 Three-phase or 18 Single-phase Multi Circuit Panle Meter for Cell Site

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Monitor: Grid, Generator, Air Conditioner, Lighting, etc
  • Active 2DI + Passive 4DI + 2DO
  • Up to 4 channels of Three-phase
  • or 12 channels of Single-phase
  • 2 NTC Temperature

AMC16L-DETT DC Energy Meter for Telecom Tower

Standard:

EN 61326-1-2013

EN IEC 61000-3-2:2019+A1:2021

EN 61000-3-3:2013+A2:2021

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Rated -48V DC
  • 6 DC channels
  • Utility Monitor
  • Power for Hall Sensor

AC 1 Three-phase or 3 Single-phase Energy Meter for Cell Phone Tower

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • AC or DC
  • 1 channel of Three-phase
  • 3 channels of Single-phase
  • 3 channels of DC

DC24V Auxi. Power RS485 Modbus-RTU AC Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless
  • 4 Tariffs
  • Temperature
  • Leakage Current
    Top