Single-phase WiFi Meter

ADW310-WiFi

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

  • Single-phase
  • 4G, WIFI
  • DI/DO
  • Cable Temperature

Feedback

What Do Our Customers Say?

  • Acrel is one of the best supplier for me. They are so easy to communicate and very friendly. They even give an online tour of their factory. Looking forward for more business together in the future.

    Liezel 

    Philippines

  • My first contact with ACREL was through Mrs. Feeling Chang. He was extremely friendly, approachable and very helpful. It will be the beginning of a long partnership between Bikoelectronics and Acrel.

    Vanessa 

    Portugal

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Single-phase Wireless Power Meter?

Basic Measure

  • 1-phase Active&Reactive Energy
  • Active & Reactive Power
  • Current, Voltage, Frequency
  • Power Factor, Apparent Power

Wireless Communication

  • 4G LTE & GRPS
  • WIFI(2.4&5G HZ)

Expanded Function

  • DI/DO
  • Cable Temperature
  • Residual Current

Alarm Function

  • Over / Under Power
  • Current; Voltage
  • Phase Lose

Specification

What’s the Specification of Acrel ADW310 series Single-phase WIFI Meter?

Online&Remote Energy Monitoring

● Paired with Acrel IoT Energy Monitoring System

● PC Access via IoT EMS WEB

● Mobile Phone Access via IoT EMS APP

● 4G Wireless Communication (Global)

● WiFi Wireless Communication (2.4GHz)

● Support MQTT, MODBUS-TCP protocol

● Support standard RS485 interface (MODBUS-RTU)

 Multiple Extra Function

● 1-channel DO (Digital Output)

● 1-channel DI (Digital Input)

● 2-channel Cable Temperature Monitoring

● Active Pulse Output

Alarm Function

● Over/Under Current

● Over/Under Voltage

● Over/Under Power

Parameter

What’s the Parameter of the Acrel ADW310 series Single-phase WIFI Meter?

  1. Function Overview
Function Description
Measurement

(Standard)

Single-phase AC Active&Reactive Energy (both forward and backward), Active Power, Reactive Power, Current, Voltage, Frequency, Power Factor, Apparent Power, Frequency
Measurement

(Optional)

Temperature Measurement:2-channel (Live line,Neutral line) Cable Temperature Monitoring;  Thermistor:NTC;  Range: -40~+99℃;  Accuracy:±2℃
Communication

(Standard)

RS485 Port with Modbus-RTU protocol –  1 start bit,8 data bits,1 stop bit, no parity;  Baud Rate 1200~38400 bps, etc.

Infrared Communication – Constant Baud Rate 1200 bps

Communication

(Optional)

 

 

4G LTE – Normal Communicaiton Module Support: LTE-FDD: B1/B3/B5/B8;  LTE-TDD:B34/B38/B39/B40/B41

4G LTE – Global Communication Module Support: LTE-FDD: B1/B3/B5/B7/B8/B20/B28;  LTE-TDD: B38/B40/B41

WiFi – Support 2.4GHz or 5GHz
Protocol (For wireless Communication): MQTT and MODBUS-TCP
Display

(Standard)

LCD Display and LED Indicator
HMI

(Standard)

Keypads Programming: Setting of CT/PT Ratio, Communication, Phase Wiring and etc
Software

(Standard)

Adjustment Software: Setting of Data Upload Interval, WiFi configuration (Account&Password), Server Address, Port and etc
Alarm Function

(Standard)

Undervoltage, Overvoltage, Undercurrent, Overcurrent, Underload, Overload, Communication Disconnection and etc
I/O Function

(Optional)

1-channel DI (Digital Input)

1-channel DO (Digital Output)

 

  1. Main Parameters
Parameter Description&Value
Voltage

Input

Rated Voltage 220~264Vac L-N
Reference Frequency 45~65Hz
Power Consumption <0.5VA (each Phase)
Current

Input

Rated Current 20(100)A AC
Starting Current 1% Ib (Class 0.5); 4% Ib(Class 1)
Power Consumption <1VA (each Phase)
Phase

Wiring

1P2W 1-phase 2-wire
Measurement

Performance

Standard GB/T17215.322-2008,GB/T17215.321-2008
kWh Accuracy Class 1
Pulse Width of Pulse 80±20ms
Pulse Constant 1600imp/kWh;

 

  1. Environment
Condition Description&Value
Temperature Operating Temperature: -25℃~+55℃;  Storage Temperature: -40°C ~+70°C
Humidity ≤95%RH, no condensation, without corrosive gas
Altitude ≤ 2000m

Network

How does Acrel ADW310 series Single-phase WIFI Meter work?

Installation

How to Install the Acrel ADW310 series Single-phase WIFI Meter?

Specification Dimension (mm) Perforation size (mm) Tolerance (mm)
W H D M N Φ1 Φ2
AKH0.66-K/φ10N 27 44 32 25 36 10 9 ±1
AKH0.66-K/φ16N 31 50 36 27 42 16 17

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Single-phase 4G Electric Meter

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless Comms.:4G, WiFi (MQTT, MODBUS-TCP)
  • Wired Comms.:RS485 (MODBUS-RTU)
  • I/O Function:1-way DI & 1-way DO
  • Temperature:2-way Cable Temperature Measurement
  • Pulse Output:Active Pulse Output

IoT based MQTT WiFi Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • WIFI
  • 4G
  • LORA
  • LORAWAN

Lora Wireless Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • LORA Wireless
  • Electric Parameter
  • Residual Current
  • Cable Temperature
  • 4DI/2DO

Multi-Circuit Lora Wireless Power Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485, LORA
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current

Wireless Energy Meter with Multi Circuits

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485 Modbus-RTU
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current

Wireless Multi Circuit Economy 7 Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN IEC 61000

EN61010

Certificate:

Feature:
  • Modular Design
  • Max 12 Channels of Three-phase
  • High Accuracy 0.5s Class
  • Communication RS485, CE

Three-phase WiFi Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • WIFI
  • MQTT
  • JSON
  • 3 phase

923MHz LoraWan Power & Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • LoraWan
  • 923MHz
  • 917MHz
  • 868MHz

4G Wireless Three-phase Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 4G Wireless
  • Electric Parameter
  • Residual Current
  • Cable Temperature
  • 4DI/2DO
    Top