Wireless Multi Circuit Economy 7 Meter

ADF400L-F

  • Modular Design
  • Max 12 Channels of Three-phase
  • High Accuracy 0.5s Class
  • Communication RS485, CE

Feedback

What Do Our Customers Say?

  • “ For over 4 years working with Acrel, they have continuously demonstrated excellent technical ability while ensuring superior customer service. Their collaborative approach and real time flexibility in adapting to changing conditions has contributed to the success of many project goals. "

    Arnold 

    Philippines

  • Cloud Platform for Power IoT is a synchronous integrated solution from energy meter installation to web interactive interface that can see the benefits of features with the first click mouse. Very convenient and fast. I will be with this product for a long time.

    Tuan 

    Vietnam

Highlight

What’s the Function of Acrel ADF400L Series Wireless Multi Circuit Economy 7 Meter?

Monitor

  • Electrical Parameters;
  • Voltage, Current, Power, Reactive Power, Apparent Power, Power Factor, Kilowatt-hours, Kilovar-hours etc.

 Tariff

  • 1~4 kinds of Tariffs
  • Peak
  • Standard
  • Off-peak
  • 14 Time period by day

Modular

  • Current Input Directly or via Current Transformer;
  • 3*10(80)A, 3*1(6)A

Extendible

  • 12 modules at most;
  • Din-rail installation

Specification

What’s the Specification of Acrel ADF400L series Wireless Multi Circuit Economy 7 Meter?

Compact Modular Design

● Main Body (LCD&Keypads HMI)

● 1-phase Metering Module

● 3-phase Metering Module

● Expanded Communication Module

Multi Circuits Metering for 1-phase&3-phase

● 3 Types of Multi-circuits Combination

● Max 36 Circuits 1-phase Metering

● Max 12 Circuits 3-phase Metering

● Mixed (1-phase&3-phase Circuits Metering)

Remote Switch Control

● Control&Read Status of Switches

● 2 DO&2 DI (Main Body)

● Dry Contact DI (Main Body)

● 4 DO&4 DI (CT operated Sub Module)

● 220V AC Wet Contact DI (CT operated Sub Module)

Parameter

What’s the Parameter of Wireless Multi Circuit Economy 7 Meter?

Parameter Description&Value
Auxiliary

Power Supply 

Voltage 3*220V/380V (for 3-phase sub modules)
Power Consumption ≤10W
 Input 

Voltage

Rated Voltage 3x 220/380V AC (3-phase)
Frequency 50Hz
Input

Current

Rated Current Max 80A Load Current (for 1-phase&3-phase sub module with direct connection); 3×1(6)A(for 3-phase sub module via CTs)
Starting Current 1‰ Ib (Class 0.5S)
Accuracy Measurement Class 0.5
Clock ≤0.5s/d
 

Pulse

Pulse Output 1 Active Energy Pulse for each 3-phase Sub Module
Pulse Width 80ms±20ms
Pulse Constant 6400imp/kWh (3-phase)
Communication RS485 MODBUS-RTU
Infrared For Prepaid Card Scanning
Ethernet MODBUS-TCP
Environment Operating Temperature -20℃~+60℃
Storage Temperature -30℃~+70℃
Humidity ≤95% (No condensation)
Altitude <2000m

Installation

How to Install the Wireless Multi Circuit Economy 7 Meter?

Main Body Sub Module (Direct Connect) Sub Module (Via CTs)
Direct Connect (1-phase&3-phase) Connect via CTs (3-phase)

Why choose Acrel?

  • 2003 Established
  • SZ.300286 Listed Company
  • 1200+ People
  • 25000+㎡ Plant
  • Factory Direct-sale

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

FAQ

Got a Question? Get your Answer

What are the Main Advantages of Acrel?

We have our own Factory and R&D Center

What are the Difference between Acrel and other Brands?

Rich product series: Cloud Platform, Gateway, Protection Device, Power Meter, Transformer

What Certificates does the Company have?

CNAS, ISO14001, ISO27001, ISO9001

What Certificates do the Products have?

CE, IEC, MID, UL, EAC, ROHS, REACH

How Expensive is Acrel Products?

Competitive Price with High Quality

How long is the product Warranty Period?

2 Years

What is the MOQ?

Purchasing according to your needs, no MOQ limit

How long is the Lead Time?

Sample takes 3 days; Bulk purchase takes 1 month

Lora Wireless Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • LORA Wireless
  • Electric Parameter
  • Residual Current
  • Cable Temperature
  • 4DI/2DO

923MHz LoraWan Power & Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • LoraWan
  • 923MHz
  • 917MHz
  • 868MHz

Three-phase WiFi Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • WIFI
  • MQTT
  • JSON
  • 3 phase

Wireless Energy Meter with Multi Circuits

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485 Modbus-RTU
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current

Single-phase 4G Electric Meter

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless Comms.:4G, WiFi (MQTT, MODBUS-TCP)
  • Wired Comms.:RS485 (MODBUS-RTU)
  • I/O Function:1-way DI & 1-way DO
  • Temperature:2-way Cable Temperature Measurement
  • Pulse Output:Active Pulse Output

IoT based MQTT WiFi Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • WIFI
  • 4G
  • LORA
  • LORAWAN

4G Wireless Three-phase Power Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 4G Wireless
  • Electric Parameter
  • Residual Current
  • Cable Temperature
  • 4DI/2DO

Single-phase WiFi Meter

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Wireless Comms.:4G, WiFi (MQTT, MODBUS-TCP)
  • Wired Comms.:RS485 (MODBUS-RTU)
  • I/O Function:1-way DI & 1-way DO
  • Temperature:2-way Cable Temperature Measurement
  • Pulse Output:Active Pulse Output

Multi-Circuit Lora Wireless Power Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN 61010

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • Split-core Current Transformer with RJ12 Interface
  • 4 Channels of Three-phase
  • Communication RS485, LORA
  • Optional Function: 12DI/4DO, 12 Temperature, 4 Leakage Current
    Top