Energy Efficiency Management System Solution for Water Treatment Plant Substation

In the water conservancy industry, sewage treatment plants and pumping and drainage stations are large consumers of electricity.

Renovating old facilities to improve efficiency, save electricity, tap the potential of energy conservation and emission reduction,

and help achieve carbon peak and carbon neutral goals.

Difficulty

What's the Difficulty of Water Treatment Energy Efficiency Management?

  • High Energy Consumption
  • Unstable Power Supply
  • Isolated information islands

Highlight

What's the Highlight of Smart Water Treatment Energy Efficiency Management?

  1. Energy saving
  2. Improve the quality of power supply
  3. Operation and maintenance assistance

Distribution Structure

What's the Distribution Structure for Smart Water Treatment Energy Efficiency Management System?

If the power supply of the urban sewage treatment project is interrupted, it will have a serious impact on the life of urban residents and environmental protection.
In order to ensure the continuous and reliable operation of the sewage treatment plant, its electricity load is determined to be Class II.
Two 35kV power sources are led from the upper-level substation to the high-voltage power distribution room of the sewage plant, and the two 10kV power sources are connected in single-female section belts, which can meet the power consumption requirements of the secondary load.
At the same time, in order to ensure the reliability of the power supply, a diesel generator is spared, which can at least meet the power consumption of emergency ventilation, fire fighting, and emergency lighting in the factory.

Management System Structure

What's the Smart Water Treatment Energy Efficiency Management Structure?

Energy saving:
Perfect measurement system;
Energy consumption statistics;
Energy flow analysis;
Process production energy consumption data monitoring;
Lighting control;
Load regulation.

Improve power supply reliability:
Real-time monitoring of medium and low voltage;
Power Quality Monitoring and Improvement;
Transformer, generator, process equipment condition monitoring;
Junction temperature monitoring;
Real-time warning.

Operation and maintenance assistance:
Equipment Ledger;
Equipment Maintenance Reminder;
Work order distribution;
Closed-loop operation and maintenance process;
Expert report.

Function

What's the Function of Smart Water Treatment Energy Efficiency Management?

Power Monitoring

(1) Real time monitoring
Real-time monitoring of high and low voltage power supply and distribution system switch cabinets, transformer microcomputer protection and control devices, generator control cabinets, motors, including remote control, remote signaling, telemetry, remote adjustment, accident alarm and records, etc.
(2) Key power supply and distribution equipment monitoring
Monitor the current, voltage, active/reactive power, power factor, load rate, temperature, three-phase balance, abnormal alarm and other data of transformers, diesel generators, motors, and process equipment.
(3) Fault recording
The system has fault wave recording and event sequence recording, which are used to analyze fault waveforms, assist in analyzing the cause of faults and improve them.
(4) Power Quality Monitoring
Monitor the power quality of each incoming circuit, including data waveform records such as voltage sag, harmonic distortion, flicker, etc., and then judge the disturbance direction of the power distribution system.

Electrical Safety

(1) Power quality control
Configure active filtering devices and reactive power compensation devices to compensate and control the power quality at the 0.4kV side, and monitor the operation of active filtering devices and reactive power compensation devices to ensure that the power quality meets production requirements.
(2) Electrical fire monitoring
Monitor the leakage current and cable temperature of the power distribution system circuit to realize early warning of water and electrical safety.
(3) Fire-fighting equipment power monitoring and evacuation instructions
Monitor whether the working power of the fire fighting equipment is normal, and ensure that the fire fighting equipment can be put into use normally in the event of a fire.
(4) Node temperature measurement
The system monitors the contact temperature of circuit breakers, busbars, cable connectors, and intensive bus ducts and gives real-time warnings.

Energy Saving

(1) Construction of measurement system
Build a metering system for the sewage plant, display energy flow and energy consumption, and help it analyze the whereabouts of energy consumption through the energy flow diagram, and find out abnormal areas of energy consumption.
(2) Energy consumption data statistics
Collect the consumption of factory process electricity, factory service electricity, etc., compare and analyze year-on-year comparisons, calculate total energy consumption and energy intensity, calculate standard coal calculations, and statistical trends of CO2 emissions.
(3) Process energy consumption
Collect the energy consumption of process equipment in the sewage plant, including energy consumption data such as lift pumps, aeration systems, mixing systems, sludge treatment systems, and deodorization systems.
(4) Intelligent lighting control
Single control, area control, automatic control, induction control, timing control, scene control, dimming control and other control methods.

Operation & Maintenance Management

(1) Equipment file management
Configure important equipment including transformers, electrical cabinets, high-voltage cables, air-conditioning hosts, motors and other equipment information, and configure QR codes.
(2) Operation and maintenance process management
Task management, inspection records, defect records, fire alarm records, emergency repair records, notification work orders
(3) Equipment maintenance
After the user maintains the equipment's warranty period and installation time, it detects whether the equipment has been running for a long time or expired, reminds the user to check or replace the corresponding equipment in time, and prompts maintenance or replacement suggestions.
(4) Expert diagnosis report
The system regularly generates energy consumption analysis reports for users and provides expert advice.

Related Products

Remote I/O Integration Modules

Feature:
  • DI/DO
  • AI/AO
  • Modbus-RTU RS485
  • Modbus-TCP Ethernet CE

MV Switchgear Controller

Feature:
  • 3~35KV Switchgear
  • AC or DC Power Supply
  • SLD Dynamic Simulation Instruction
  • Modbus Protocol

Power Quality Analyzer

Standard:

2014/35/EU

2014/30/EU

Certificate:

Feature:
  • Quality Analysis
  • Multi-Communication
  • High Precious 0.2s
  • 32G SD Card

Three-phase WIFI MQTT Energy Meter

Standard:

2014/30/EU

EN IEC 61000

IEC 62052

IEC 62053

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • WIFI
  • MQTT
  • JSON
  • 3 phase

Wireless Temperature Monitoring System for Switchgear

Standard:

CE

Certificate:

Feature:
  • Wireless Temperature
  • Report Download
  • Curve Analysis
  • Web & APP Access

Protection & Control Motor Relay

Standard:

IEC 60947-4-1:2018

IEC 60947-5-1:2016

Certificate:

Standard Lead Time:
Sample: 2 days
Bulk: 1 month

Feature:
  • 660V Low Voltage Motor
  • Measure, Protect, Control
  • 10DI/6DO, 2AI DC4-20mA
  • Modbus-RTU, Profibus, Profinet, Ethernet

Protective Relay

Feature:

8 current input, 4 voltage input

16 DI, 10 DO

2 RS485, 1 RS232, 1 GPS

Powerful graphic programmable Logic

Multi Circuit Economy 7 Meter

Standard:

2014/30/EU

EN IEC 61000

2014/35/EU

EN IEC 61000

EN61010

Certificate:

Feature:
  • Modular Design
  • Max 12 Channels of Three-phase
  • High Accuracy 0.5s Class
  • Communication RS485, CE

Split Core Current Transformer for Cable

Standard:

IEC 61558-1

IEC 61558-2-15

IEC60364-7-710

Certificate:

Feature:
  • Capacity: 3.15, 5, 6.3, 8, 10 KVA
  • Noise Level: <40dB
  • Insulation Class: H
  • Short Circuit Voltage ≤ 3%
  • No-load Output Current ≤ 3%
  • Inrush Current ≤ 12 In
  • Leakage Current <0.2mA
  • Efficiency >96%

Request Information & Quotation

Kindly Fill out the Form below and tell us more about your Requirements,
We would like to provide Suitable Solution for You.
or Send us Email directly, [email protected]

If you have more detailed requirements, Please go to the relevant product page to submit the form.

    ... ...
    Top